Help › Drawing › Getting started

Getting started

PfdLabs is a process flow diagram editor for mineral processing, hydrometallurgy, pyrometallurgy and recycling. You draw the flowsheet from ready-made equipment symbols, connect it with streams and, on Yearly and Lifetime plans, calculate the mass and metal balance on the same diagram.
The editor: top bar, symbols on the left, the diagram in the middle and the properties of the selected item on the right.
The editor: top bar, symbols on the left, the diagram in the middle and the properties of the selected item on the right.

The editor at a glance

AreaWhat you find there
Top barBack to the Dashboard, diagram name and save status, Undo and Redo, the Select, Connect and Text tools, Templates, dark mode, Help, Share, the active case, the view mode, the balance status, Export and Save.
Left panelBasic shapes, your own images and 290 equipment symbols in three styles. See Symbols and shapes.
CanvasYour diagram. Drag the empty canvas to pan, scroll to zoom. See Canvas, saving and files.
Right panelProperties of what is selected: a node, several nodes (with alignment), or an arrow with its stream data and balance.
Floating toolbarAppears under a selected node: duplicate, bring to front, send to back, rotate by 90° and delete.
Bottom barZoom, Fit, grid style, Snap to grid and connection Handles. The minimap sits in the corner.

Your first diagram in six steps

  1. Click Templates to start from a ready flowsheet, or start with an empty canvas.
  2. In the left panel choose a symbol style (3D, 2D or Simplified) and click a symbol, for example Ball Mill. It appears in the middle of the view. Drag it into place.
  3. Add the other units the same way. Turn on Snap in the bottom bar so they line up on the grid.
  4. Choose Connect in the top bar, click the first unit and then the second. A stream arrow is drawn between them. Press Escape or choose Select to stop connecting.
  5. Click a unit or an arrow and adjust it in the right panel: name, colours, size, arrow style and stream data.
  6. Name the diagram by clicking its title in the top bar, then press Save (Ctrl+S). It is stored in your account and listed in the Dashboard.
Templates: ready flowsheets, three of them with a complete mass and metal balance.
Templates: ready flowsheets, three of them with a complete mass and metal balance.
Help › Drawing › Symbols and shapes

Symbols and shapes

The left panel holds everything you can place on the canvas: 290 equipment symbols in three drawing styles, basic shapes, text and your own images.
The symbols panel: style, search, area and category filters, favourites.
The symbols panel: style, search, area and category filters, favourites.

Three symbol styles

StyleLooks likeGood for
3Dshaded isometric equipmentpresentations, proposals, websites
2Dflat coloured drawingsreports and manuals
Simplifiedblack line drawings in the ISO / PFD styleengineering documents and printing

You can mix styles in one diagram, but a single style looks more professional. The style you choose is remembered for the next time.

Finding a symbol

ToolHow it works
SearchType part of the name, for example thick or cyclone. The search covers all 290 symbols in all styles.
AreasGeneral (comminution, classification, separation, storage, transport), Hydromet (leaching, CIL/CIP, SX/IX, precipitation, tanks), Pyromet (roasting, smelting, converting, slag, refining, off-gas, handling) and Recycling (sorting, battery, e-waste, storage).
CategoriesNarrow an area down, for example Hydromet → Leaching.
Favourites ★Hover a symbol and click the star. All starred symbols are collected under ★ Favourites, separately for each style.

Click a symbol to place it in the middle of the current view. Hover it to see its full name.

Basic shapes

ShapeTypical use
Boxa general process step, a unit without a symbol, a legend
Deviceorange box for equipment or instruments
Circle, Ellipsestart and end points, sample points, tanks drawn schematically
Diamonddecisions and splits in block diagrams
Triangle, Arrowstockpiles, direction marks
Pillfeeds and products, for example “ROM ore” or “Cu concentrate”
Textfree text without a frame: titles, notes, area names

Your own images

Click Image to upload a picture from your computer, for example your company logo, a photo of the plant or a symbol you drew yourself. It is placed in the middle of the view and can be moved, resized, rotated and connected like any other node. Images are saved inside the diagram, so keep them small (a few hundred kB).

Feeds and productsStart a flowsheet with a pill or an Ore Pile symbol (“ROM ore”) and end it with pills for the products. The mass balance treats units without inputs as the plant feed and units without outputs as products.
Help › Drawing › Editing equipment and shapes

Editing equipment and shapes

Select a node to move, resize, rotate, rename, recolour or delete it, and to add its equipment tag and process data.
A selected node: the round rotation handle above, the resize handle in the bottom-right corner and the floating toolbar below.
A selected node: the round rotation handle above, the resize handle in the bottom-right corner and the floating toolbar below.

Select, move, resize, rotate

ActionHow
Selectclick the node (the Select tool must be active)
Movedrag it; with the arrow keys 1 px, with Shift + arrow 10 px
Resizedrag the orange handle in the bottom-right corner. The proportions are kept, so symbols never get distorted
Rotate freelydrag the round handle above the node
Rotate exactlytype the angle in Rotate in the right panel, or click ↻ in the floating toolbar for 90° steps
Renamedouble-click the node and type
Deselectclick the empty canvas or press Escape

Properties

Node properties and process data in the right panel.
Node properties and process data in the right panel.
FieldMeaning
Labelthe name shown under (or inside) the node
Fill, Borderbackground and outline colour of shapes
Text, Fontcolour and size of the label
W, Hwidth and height in pixels
Radiuscorner rounding of boxes (0 = sharp)
Rotateangle in degrees

Shapes have fill and border colours; equipment symbols keep their drawing and only the label can be styled.

Right-click a node for its menu.
Right-click a node for its menu.
CommandWhat it does
Renameedit the label
Duplicate (Ctrl+D)a copy next to the original
Bring to front / Send to backchange which node is drawn on top, for example to put a panel behind the equipment
Rotate 90°in the floating toolbar
Deleteremoves the node together with its arrows

Equipment tag and process data

Under Process data enter the tag (for example ML-101), the throughput with its unit (t/h, m³/h, kg/h, Mt/a, t/d, m³/d) and the installed power in kW. The tag is shown in orange under the label and the values below it; untick Show to hide them on the drawing. Export → Equipment list writes every unit with its tag, symbol style, throughput and power into Excel, with the total installed power.

NamingUse the same tag system as in your plant or project, for example ML-101 for mill 1 in area 100. The equipment list and the balance tables are sorted by tag and stream number.
Help › Drawing › Arranging and aligning

Arranging and aligning

Work with several nodes at once, line them up, space them evenly and keep the flowsheet tidy.

Selecting several nodes

ActionHow
Add to the selectionShift + click each node
Select everythingCtrl + A
Move togetherdrag any of the selected nodes, or use the arrow keys
Copy and pasteCtrl + C, Ctrl + V. Arrows between the copied nodes are copied too
DuplicateCtrl + D
DeleteDelete or Backspace
Four selected units are outlined in blue; the Align panel appears in the right panel.
Four selected units are outlined in blue; the Align panel appears in the right panel.

Align and distribute

The Align panel (two or more nodes selected).
The Align panel (two or more nodes selected).
ButtonResult
← Left, Right →left or right edges in line
↔ Centervertical centre lines in line (one under another)
↑ Top, Bottom ↓top or bottom edges in line
↕ Middlehorizontal centre lines in line: the usual choice for a process train
Distribute H / Vequal gaps between the nodes, horizontally or vertically. The first and last node stay where they are
Before: units placed by hand.
Before: units placed by hand.
After Middle and Distribute H: one line, equal gaps, straight arrows.
After Middle and Distribute H: one line, equal gaps, straight arrows.

Grid and snapping

Snap in the bottom bar moves nodes on a 20 px grid while you drag them, so rows and columns line up by themselves. Grid switches the background between lines, dots and no grid. The grid is never exported.

Layers

Nodes are drawn in the order they were added. Use Bring to front and Send to back to change it. A typical use is a large light Panel or box sent to the back to frame an area such as “Grinding” or “Flotation”.

Tips for a professional flowsheet

GRINDINGFLOTATIONBall millCycloneRougherCleanerwater from the toptailings downrecycle dashed, below
  • Flow from left to right (or top to bottom), with feed on the left and products on the right.
  • One row per process train: use Middle and Distribute H.
  • Recycles below the main line, drawn dashed; water and reagents come from the top, tailings go down.
  • Group areas in panels with a short title in capitals.
  • Same style, same size: one symbol style and similar sizes for similar equipment.
  • Number the streams in the direction of flow (S1, S2 …) and tag the equipment.
Help › Drawing › Connecting streams

Connecting streams

Arrows connect the units and carry the streams: their style, ports, colour and line type, labels and stream data.

Drawing an arrow

  1. Choose Connect in the top bar.
  2. Click the unit the stream leaves. Click near the side you want it to leave from (with Handles on you see the four connection points).
  3. Click the unit it goes to, again near the side where it should enter.
  4. Repeat for the next stream. Press Escape or choose Select to finish.

The new arrow takes the style chosen in the arrow style selector. If you click in the middle of a unit, PfdLabs picks the sides facing each other.

Arrow styles

SmoothStraightAngleCurvedSmooth Angle
StyleUse
Smooth Anglethe standard for flowsheets: right angles with rounded corners. Used in all templates.
Angleright angles with sharp corners, the classic engineering look
Straightshort direct connections
Smooth, Curvedblock diagrams and sketches

Ports

UnitNESWCycloneFlotationBall millE → WS → NFour ports on every unit

Every unit has four ports: North, East, South, West. Select an arrow and set From Port and To Port in the right panel. Changing ports is the main way to route arrows neatly: a recycle from the cyclone underflow back to the mill looks best from South to South, a feed from East to West, a water addition from North (from above).

Arrow properties: label, colour, width, ports, style, arrowheads and line type.
Arrow properties: label, colour, width, ports, style, arrowheads and line type.

Look of the arrow

FieldOptions
Labeltext in the middle of the arrow, for example “overflow”. Double-click an arrow to edit it
Color, Widthany colour, line width in px
Arrownone, at the end, at the start or both ends
Linesolid, dashed or dotted

Delete edge removes the arrow; selecting it and pressing Delete works too.

Colour and line conventions

There is no single standard, but these are widely understood:

StreamSuggested look
Ore and slurry, main processgrey or dark blue, solid
Recycle (circulating load, cleaner tails)orange or red, dashed
Waterblue, solid
Solutions (PLS, raffinate, electrolyte)cyan
Organicyellow
Reagentsgreen, thin
Air, gas, off-gaslight grey, dotted
Signals, control linesdotted, thin

Stream data

Each arrow also carries stream data: stream number, flow with its unit and % solids, shown as a label on the drawing (untick Show to hide it). On Yearly and Lifetime plans the same arrow holds the balance inputs. See Mass balance basics.

Avoid overlapping arrowsTwo arrows between the same units (for example a cyclone feed and its underflow back to the mill) should use different ports, otherwise they lie on top of each other and only one label is visible.
Help › Drawing › Canvas, saving and files

Canvas, saving and files

Navigate large flowsheets, keep your work safe and move diagrams between devices and people.
ActionHow
Pandrag the empty canvas
Zoommouse wheel (zooms around the cursor) or + and − in the bottom bar
FitFit in the bottom bar shows the whole diagram
Minimapthe small overview in the corner; the orange frame is your view. Click it to fit
Dark modethe Dark button in the top bar. Exports always have a white background
The same flowsheet in dark mode.
The same flowsheet in dark mode.

Saving

  • Save (Ctrl+S) stores the diagram in your account. The status next to the name shows Saved or Unsaved changes.
  • Autosave runs every 30 seconds for Pro users, and for Free users once a diagram has been saved the first time.
  • Undo and Redo (Ctrl+Z, Ctrl+Y) keep the last 50 steps.

Dashboard

The Dashboard lists your diagrams. Open, rename, duplicate or delete them there. The Free plan keeps 5 diagrams in the cloud, Pro plans are unlimited.

Files

CommandWhat it does
Export → Download as file (.json)saves the complete diagram, including stream data, balance settings and cases, as a file on your computer. Unlimited on every plan
Export → Open file…opens such a .json file again
New diagramclears the canvas after asking
Templatesopens a ready flowsheet

Phones and tablets

The editor is made for a computer with a mouse. On a phone you can open it, but a note recommends a larger screen. Shared links (Share) work well on phones.

Keyboard shortcuts

KeysAction
Ctrl + Z / Ctrl + YUndo / redo
Ctrl + SSave
Ctrl + C / Ctrl + VCopy and paste the selection with its arrows
Ctrl + DDuplicate
Ctrl + ASelect all
Delete / BackspaceDelete the selection
Arrow keysMove 1 px (with Shift 10 px)
EscapeDeselect or stop connecting
Shift + clickAdd to the selection
Double-clickRename a node or edit an arrow label
Right-click a nodeContext menu
Mouse wheelZoom around the cursor
Help › Drawing › Export, share and view modes

Export, share and view modes

Get your diagram out of PfdLabs as an image, a document or a live link, and choose what is shown on it.

Export

FormatWhat you getPlan
PNG imageRaster image cropped to the diagram, white background. Free plan with a small watermark.All
SVG vectorScalable drawing for Illustrator, Inkscape or Word.All
PDF documentPrint-ready PDF of the diagram.Pro
Equipment list .xlsxAll equipment with tags, throughput and power, plus the stream list.All signed-in
Stream table (balance) .xlsxStream table, unit balances, equipment sizing, reagents and cases.Yearly, Lifetime
Balance reportPrintable report with the diagram and all balance tables. Save it as PDF from the print dialog.Yearly, Lifetime
Download as file .jsonThe diagram as a file you can open again with Open file. Unlimited, also on the Free plan.All

Share a read-only link

  1. Save the diagram, then click Share in the top bar.
  2. Switch the link on and copy it.
  3. Anyone with the link can pan and zoom the diagram on a computer or a phone. They cannot edit it and they do not need an account.

The shared page always shows the last saved version. You can switch the link off at any time; switching it on again brings back the same link. If your plan includes the balance, the people you share with see the balance too: coloured stream labels, calculated values and unit status.

View modes

The 👁 selector in the top bar decides what is drawn on the diagram. It is saved with the diagram and it is also what PNG and PDF exports and shared links show.

ModeWhat is shownTypical use
BalanceStream labels with entered and calculated values, unit status, circulating load.Working on the balance
Stream dataOnly the values you entered on the arrows.Data sheets, design reviews
Diagram onlyThe flowsheet without any stream data. Arrow labels and equipment tags stay.Sharing with suppliers, presentations
SankeyArrow width proportional to a flow. See Sankey view.Showing where the metal goes
The same flowsheet in the <b>Diagram only</b> mode.
The same flowsheet in the Diagram only mode.
Help › Mass & metal balance › Mass balance basics

Mass balance basics

Enter what you know on the streams. PfdLabs calculates the rest, checks every unit and shows you where the numbers do not add up.

The idea

Every arrow is a stream, every symbol with arrows going in and out is a unit. For every unit, what goes in must come out: solids, water and every metal. PfdLabs writes these balances for the whole diagram, fills in the values you did not enter and flags the units that do not close.

What you enter

  1. Click an arrow. In Stream data enter the stream number, the flow and the unit, and the % solids.
  2. In the Balance section choose the stream type (Slurry, Solution, Organic or Water) and, for slurries, the solids SG (default 2.8).
  3. Add components once per diagram (Cu %, Au g/t…) and enter grades on the streams you have assays for.
An arrow selected: stream data, the balance inputs and the calculated values.
An arrow selected: stream data, the balance inputs and the calculated values.

What PfdLabs calculates

ResultFrom
Water, slurry mass and volume, pulp densitySolids flow, % solids and solids SG (see Slurry formulas)
Missing flows, % solids and gradesThe balance of each unit, one unknown at a time
Concentrate and tailings flowsThe two-product formula from grades
Metal flows, recovery, enrichment ratio, mass yieldFlows and grades (see Metal balance)
Circulating loadRecycle streams found in the diagram (see Circulating load)

Calculated values are shown in purple and carry a calc tag on the arrow. Values you entered are shown in dark blue.

One unknown per unit

For each unit PfdLabs looks at all the streams around it. If exactly one value is missing (for example the flow of one stream), it is calculated from the others. The newly known value may then complete the balance of the next unit, so the calculation spreads through the whole flowsheet. It is repeated for solids, water and every component.

Unite.g. pump boxS2 · 450 t/hS5 · 1 125 t/hS3 · 1 575 t/h calcknownthe only unknown → calculated✓ balanced
The pump box receives 450 t/h from the SAG mill and 1 125 t/h from the ball mill, so its discharge must be 1 575 t/h.
Leave exactly one value emptyEnter everything you measured and leave the stream you did not measure empty. If you enter all streams around a unit and they do not agree, the unit shows a warning, and data reconciliation can adjust them.

Balance check and warnings

Each unit shows its status above the symbol. Calculated values have a purple calc tag.
Each unit shows its status above the symbol. Calculated values have a purple calc tag.
BadgeMeaning
✓ balancedSolids, water and every metal close within 0.5 %.
⚠ out − in = −12 t/hSolids do not close. More solids enter the unit than leave it (or the opposite).
⚠ Cu out − in = −3.83 t/hA metal does not close: flows × grades in and out differ.
⚠ water out − in = +39 t/hAll water flows around the unit are known and they differ. If water is added (spray or wash water), draw it as a Water stream and leave it empty.
⚠ negative flow in S7Closing the balance would need a negative flow. Check the values around the unit.

The status button in the top bar counts the units with a warning: Mass & metal balance: OK or Mass balance: 2 warnings. Click it to open the stream table.

Click a unit to see its balance: streams in and out, difference, mass yield, recovery and enrichment ratio.
Click a unit to see its balance: streams in and out, difference, mass yield, recovery and enrichment ratio.

The stream table

Click the status button in the top bar to open the table under the diagram. It lists every stream with its type, solids, % solids, water, volume, pulp density and, for each component, grade, concentration, metal flow and recovery. Click a row to select the arrow. Export to Excel writes the same table and more.

The stream table. Purple values are calculated.
The stream table. Purple values are calculated.
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Slurry formulas

Slurry formulas

How PfdLabs turns solids flow and % solids into water, slurry flow and pulp density, with the formulas you can check by hand.
Mass (t/h)solids 500water 929slurry 1 429 t/hVolume (m³/h)solids 179water 929slurry 1 107 m³/h · pulp density 1.29 t/m³
Stream S6 of the concentrator template: 500 t/h of solids at 35 % solids and SG 2.8.

Formulas

QuantityFormulaS6 example
WaterW = S × (100 − p) / p500 × 65 / 35 = 928.6 t/h
Slurry massM = S + W1 428.6 t/h
Solids volumeVs = S / SG500 / 2.8 = 178.6 m³/h
Slurry volumeV = S / SG + W / 1.01 107.1 m³/h
Pulp densityρ = M / V1.29 t/m³
% solids from waterp = 100 × S / (S + W)used when water is known from the balance

S is the solids flow (t/h), p the solids content in % by weight, SG the specific gravity of the solids and W the water flow (t/h, equal to m³/h). Water density is taken as 1.0 t/m³.

Solids SG

Each slurry stream has its own Solids SG, by default 2.8. Concentrates are usually heavier than the ore, for example 4.1 for a copper concentrate. To set the same SG on every stream, use Apply to all in the stream table header.

Flow units

Unit on the arrowUsed as
t/hsolids flow
kg/hsolids flow / 1 000
t/dsolids flow / 24
Mt/asolids flow × 10⁶ / operating hours
m³/h, m³/dflow of solutions and water

Pipe velocity

For any stream, enter the inner pipe diameter in Pipe ID (mm) to get the velocity. Without a diameter, PfdLabs suggests the diameter for 2 m/s. Slurries below about 1.5 m/s may settle in the pipe and are marked in orange.

v  =  Q / 3 600π · D² / 4
v in m/s, Q in m³/h, D in m. Example: S6 with 1 107 m³/h needs 442 mm for 2 m/s; in a 250 mm pipe it would flow at 6.3 m/s.
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Metal balance and recovery

Metal balance and recovery

Add components such as Cu, Au, Fe or Ni, enter grades on the streams and get metal flows, recoveries, enrichment ratios and the grade of every unmeasured stream.

Components

  1. Open the stream table (status button in the top bar).
  2. Type the symbol, for example Cu, choose its unit and click + Component.
  3. The component appears as a field on every arrow. Enter the grades you know.
UnitUse forMetal flow shown as
%base metals, iron, sulphurt/h and t/d
g/tgold, silver, PGMg/h and oz/d (troy)
ppmtrace elementsg/h and kg/d
g/Lonly in solutions, e.g. H₂SO₄, NaCNkg/h and t/d

One component can be measured in two ways: as % (or g/t) in solids and as g/L in solutions. PfdLabs adds both into one metal flow, so leaching can be balanced from the ore to the cathode.

Formulas

ResultFormulaExample (rougher)
Metal flow, % gradem = S × g / 100500 × 0.80 / 100 = 4.00 t/h Cu
Metal flow, g/t gradem = S × g (g/h)500 × 0.30 = 150 g/h Au = 116 oz/d
Metal flow, solutionm = Q × C (kg/h)1 200 m³/h × 2.4 g/L = 2 880 kg/h
RecoveryR = m(product) / m(feed) × 1003.64 / 4.00 = 90.9 %
Mass yieldY = S(product) / S(feed) × 10045.5 / 500 = 9.1 %
Enrichment ratioER = g(product) / g(feed)8.0 / 0.80 = 10.0
Solidstailings 90.9 %concentrate 9.1 %Copperconcentrate 90.9 %tailings 9.1 %
The rougher sends 9.1 % of the solids but 90.9 % of the copper to the concentrate.

Where you see the results

PlaceWhat is shown
Arrow (Calculated box)metal flow per hour and per day, recovery as % of the plant feed, calculated grades
Unit (Unit balance)for each output: mass yield, recovery and enrichment ratio of each metal
Stream tablegrade, metal flow and recovery columns for each component
Labels on the diagramgrades next to the flow, for example S7 · 45.5 t/h · Cu 8.0%
Recovery of what?Recovery is measured against the plant feed: the streams that leave units with no inputs (ore pile, ROM). If the plant feed has no grade, PfdLabs uses the first streams where the metal is known and says so, for example “Cu recovery (of S3)”.

Calculating unknown grades

Metal flows are balanced like solids: if one stream around a unit has no grade, its metal flow is calculated and divided by its solids flow to give the grade. This is how the grade of a final tailings or of a mixed stream is obtained.

PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Two-product formula

Two-product formula

Calculate how much of the feed reports to the concentrate and to the tailings from assays alone. You need the feed flow and the grades of the three streams.

When to use it

On a plant you can usually measure the feed tonnage on a weightometer, and you get assays of the feed, concentrate and tailings from samples. The concentrate and tailings tonnages are rarely measured. The two-product formula fills this gap for any unit with one input and two outputs: a flotation bank, a cyclone, a spiral, a magnetic separator or a screen.

Separation(e.g. rougher)Feed F · fConcentrate C · cTailings T · tmeasuredC calculatedT calculated
F, C, T are solids flows (t/h). f, c, t are the grades of one component (for example Cu %).

The formula

Two balances must hold at the same time:

BalanceEquation
SolidsF = C + T
MetalF·f = C·c + T·t

Eliminating T gives the mass yield of the concentrate:

C / F  =  f − tc − t
ResultFormula
Mass yieldY = (f − t) / (c − t)
Concentrate flowC = F · Y
Tailings flowT = F − C
RecoveryR = c (f − t) / [ f (c − t) ]
Enrichment ratioER = c / f

Worked example

Rougher flotation from the Copper-gold concentrator template: the feed is 500 t/h at 0.80 % Cu, the rougher concentrate assays 8.0 % Cu and the tailings 0.08 % Cu.

StepValue
Y = (0.80 − 0.08) / (8.0 − 0.08)9.09 %
C = 500 × 0.090945.5 t/h
T = 500 − 45.5454.5 t/h
R = 8.0 × 0.72 / (0.80 × 7.92)90.9 %
ER = 8.0 / 0.8010.0
Try it yourself. The template has these numbers filled in. Change the tailings grade and watch the split and the recovery update.
Open this example

How to do it in PfdLabs

  1. Add the component once in the stream table: type Cu, choose %, click + Component.
  2. Click the feed arrow and enter the solids flow and the Cu grade.
  3. Click the concentrate and tailings arrows and enter only their Cu grades. Leave the flows empty.
  4. The two flows appear with a purple calc tag and the unit shows ✓ balanced. The unit panel says “Split calculated with the two-product formula from Cu grades”.

Accuracy and limits

The result is only as good as the assays. It is most sensitive when the feed grade is close to the tailings grade, which is typical for scavengers and low-grade ores:

Tailings grade tMass yieldConcentrate CChange
0.07 % Cu9.21 %46.0 t/h+1.3 %
0.08 % Cu (base)9.09 %45.5 t/h–
0.09 % Cu8.98 %44.9 t/h−1.2 %
When it does not workThe formula needs c ≠ t and a yield between 0 and 100 %. If the grades give an impossible split, the flows stay empty. With several components PfdLabs uses the first one that gives a valid split and checks the others in the metal balance. Water streams going into the unit (spray water) do not count as an input.
Measured all three flows as well?Then the balance is over-determined. Use data reconciliation to adjust flows and assays within their measurement errors.
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Circulating load

Circulating load

In closed grinding circuits, part of the material goes round and round. PfdLabs finds the recycle streams and shows how big they are compared with the fresh feed.
Ball millCycloneFresh feed 500 t/h1 750 t/h500 t/hUnderflow (recycle) 1 250 t/h↻ Circulating load 250 %to flotation
The cyclone returns its underflow to the mill. The mill and the cyclone handle 1 750 t/h although only 500 t/h enter the circuit.

Definition

CL  =  recycle flowfresh feed
expressed in %; for the circuit above 1 250 / 500 = 250 %

Why it matters

  • Sizing: the mill, the cyclone feed pump and the cyclones are sized for the circulating flow, not for the fresh feed.
  • Performance: typical ball mill – cyclone circuits run at 200–350 %. Too low gives a coarse product, too high overloads the mill and the pump.
  • Plant data: the circulating load is usually calculated from % solids or size distributions of the cyclone feed, overflow and underflow. This is the two-product formula with water or a size fraction instead of a grade.

In PfdLabs

PfdLabs walks through the diagram from the feed. A stream that leads back to a unit already passed is a recycle. When its solids flow is known, a black badge ↻ Circulating load 250% appears next to it, placed where it does not cover other labels. Recycles below 1 % (for example a carbon loop) are not shown.

The grinding circuit of the concentrator template: the cyclone underflow S5 returns to the ball mill.
The grinding circuit of the concentrator template: the cyclone underflow S5 returns to the ball mill.
Draw the recycle as it isConnect the cyclone underflow back to the mill (or the pump box). Enter the fresh feed and the underflow; the cyclone feed and overflow are calculated.
See it in the concentrator template, where the circulating load is 250 %.
Open this example
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Solutions, SX and EW

Solutions, SX and EW

Balance leach solutions, organic and electrolyte together with slurries. PfdLabs calculates SX extraction, organic loading and cathode production.

Stream types

Select an arrow and choose its type at the top of the Balance section. The colour of the label shows the type.

TypeFlowCompositionLabel colour
Slurryt/h of solids + % solidsgrades (%, g/t, ppm)blue
Solutionm³/h (or t/h with SG)g/Lcyan
Organicm³/hg/Lyellow
Waterm³/h–light blue
A solution stream: flow in m³/h, solution SG and concentrations in g/L.
A solution stream: flow in m³/h, solution SG and concentrations in g/L.

SX/EW circuit

HeapSX extractionSX strippingElectrowinningPLS 2.4 g/Lraffinate 0.25 g/Lloaded org. 7.9stripped 5.9rich 48 g/Llean 41.6Cu cathode 2.58 t/haqueous (cyan) · organic (yellow) · electrolyte loop

A unit with both an aqueous (solution) and an organic stream is treated as a solvent extraction stage. Its panel shows:

ResultFormulaTemplate value
Aqueous in / outQ of the solution streams1 200 / 1 200 m³/h
O/A ratioQ organic / Q aqueous1 300 / 1 200 = 1.08
Extraction(m aq in − m aq out) / m aq in(2 880 − 300) / 2 880 = 89.6 %
Transfer to organicm aq in − m aq out2.58 t/h Cu
Organic loadingC stripped → C loaded5.92 → 7.90 g/L
Stripping(m org in − m org out) / m org in25.1 %
The SX/EW template: the badge shows the extraction of each stage, calculated values are marked calc.
The SX/EW template: the badge shows the extraction of each stage, calculated values are marked calc.

Electrowinning and precipitation

Draw the cathode (or a precipitate) as a Slurry stream with 100 % solids and its grade (Cu 100 %). PfdLabs calculates its flow from the metal balance: rich electrolyte minus lean electrolyte. Units fed only by solutions do not check the solids balance, because solids are formed there.

StreamFlowCuCu flow
Rich electrolyte400 m³/h48.0 g/L19.2 t/h
Lean electrolyte400 m³/h41.6 g/L16.6 t/h
Cathode2.58 t/h100 %2.58 t/h = 61.9 t/d

Solution and water balance

For solutions, the liquid balance uses the solution mass (flow × SG). If a solution flow is missing, it is calculated from the liquid balance, and its concentration from the metal balance.

Open the SX/EW template with heap leach, SX, stripping and electrowinning.
Open this example
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Water balance

Water balance

Every unit balances water as well as solids. The Water balance tab shows how much water enters and leaves the plant and where it is missing.
plant boundaryProcessmills, flotation…ore moisture 15process water 913flotation water 156tailings 1 055thickener overflow 22filtrate + cake 7Water in 1 084 t/hWater out 1 084 t/h ✓
Water at the plant boundary of the concentrator template (t/h).

Plant boundary

Water in is the water in all streams that leave units without inputs: ore moisture, process water, make-up water. Water out is the water in all streams that end in units without outputs: tailings, concentrate moisture, thickener overflow, filtrate, evaporation. The difference should be zero.

The Water balance tab: water in, water out and the water of each unit.
The Water balance tab: water in, water out and the water of each unit.

Water by unit

Green units close. For the others the difference is shown. A positive difference means more water leaves than enters: usually spray, wash or dilution water that is not on the diagram.

Calculating make-up water

  1. Draw the water addition as an arrow from a node such as “Process water” into the unit.
  2. Set its type to Water and leave the flow empty.
  3. Enter % solids on the other streams of the unit. The water addition is calculated and shown with a calc tag.
SolutionsFor solution streams the liquid balance uses the solution mass (flow × SG), so a water make-up into a raffinate tank is calculated correctly.
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Time base and units

Time base and units

Work in t/h, see the results in t/d or t/a, and enter flows in the unit you have.

Flows per hour, day or year

In the stream table header choose Flows per hour / day / year and, for annual figures, the operating hours (for example 8 322 h/a = 95 % availability). Labels, panels, the stream table, the report and the Excel export are all converted. Annual values are scaled automatically to kt/a, Mt/a and koz/a.

HourlyDaily (× 24)Annual (× 8 322 h)
500 t/h ore12 000 t/d4.16 Mt/a
3.24 t/h Cu77.8 t/d27.0 kt/a
112 g/h Au86.5 oz/d30.0 koz/a

Enter flows in any unit

The flow field on each arrow accepts t/h, m³/h, kg/h, t/d, m³/d and Mt/a. Mt/a is converted with the operating hours: 4.161 Mt/a at 8 322 h/a is 500 t/h.

Saved with the diagramThe time base and the operating hours are stored in the diagram, so shared links and other devices show the same units.
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Mass & metal balance › Cases

Cases

Keep several sets of input values on one flowsheet, for example design and nominal, maximum throughput, a lower head grade or the wet season, and compare the results side by side.

Create a case

  1. Choose + New case… in the case selector in the top bar (or + Create a second case in the Cases tab).
  2. Name it. The current values become the Base case and the new case starts as a copy.
  3. Change only what differs, for example the feed 600 t/h instead of 500.
  4. Switch cases in the top bar. The diagram, panels, stream table and shared link show the active case.

The flowsheet, the arrows, stream types and stream numbers are the same in all cases. Only the input values change: flows, % solids, grades, concentrations and SG.

Compare

The Cases tab: results of every case side by side, differences against the first case in orange.
The Cases tab: results of every case side by side, differences against the first case in orange.

The comparison lists the plant feed, the solids, metal flow and recovery of every end product, the water entering the plant, the maximum circulating load and the number of warnings. Differences against the first case are in orange with the change in % (or in percentage points for recoveries).

Excel

The export contains a stream sheet for each case and a Cases sheet with the comparison.

Good to knowUndo does not go back across a case switch, so that values of two cases never mix. Reagent doses and equipment sizing inputs are shared by all cases.
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Engineering tools › Equipment sizing

Equipment sizing

Preliminary sizes of tanks, flotation cells, thickeners, filters and pipes, straight from the balance.

How it works

Click a unit. Under its balance, Equipment sizing takes the feed of the unit from the balance (slurry volume and solids) and asks only for the design parameter. The method is suggested from the name of the unit and can be changed.

Rougher flotation: four cells for 12 minutes residence time, and the reagents dosed at this unit.
Rougher flotation: four cells for 12 minutes residence time, and the reagents dosed at this unit.

Tanks and flotation cells (residence time)

V  =  Q × t × k1 − air
InputMeaningTypical
Residence time tminutes or hoursflotation 8–20 min (plant), leach and CIL 12–48 h
Number of unitsthe volume is split between them
Air hold-upshare of the cell volume taken by airflotation 10–20 % (default 15), tanks 0
Scale-up factor klab to plant residence time1.5–2.5 for flotation

Example: the rougher receives 1 238 m³/h (S6 plus flotation water). 12 min at 15 % air hold-up needs 291 m³, that is 4 × 72.8 m³.

Thickeners (solids flux)

ResultFormula
AreaA = S / flux
DiameterD = √(4A / π)
Unit areaA / (S × 24) m²/(t/d)
Rise rateQ overflow / A m/h, orange above 3 m/h
Concentrate thickener: 12.5 t/h at 0.25 t/m²/h needs 49.9 m², 8.0 m diameter.
Concentrate thickener: 12.5 t/h at 0.25 t/m²/h needs 49.9 m², 8.0 m diameter.

Filters (filtration rate)

A = S × 1 000 / rate / availability. 12.5 t/h of concentrate at 300 kg/m²/h and 85 % availability needs 48.9 m².

Pipes

See Slurry formulas → Pipe velocity.

PreliminaryResidence times, fluxes and filtration rates must come from test work or from operating data. PfdLabs does the arithmetic; it does not replace vendor sizing. Mills and cyclones are not sized yet.

All sizing results are in the Equipment sizing sheet of the Excel export and in the report.

PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Engineering tools › Reagents and cost

Reagents and cost

Enter the reagents dosed at each unit and get the consumption and the cost per hour, per day, per year and per tonne of ore.

Add reagents

  1. Click a unit, for example the rougher.
  2. Under Reagents click + Reagent, type its name, the dose and the price per kg.
  3. Choose the dose unit:
Dose unitConsumption
g/t oredose × plant feed solids / 1 000 (kg/h). This is how consumption is usually reported.
kg/t oredose × plant feed solids
g/t unit feeddose × solids fed to this unit / 1 000, for example for cleaners
kg/hfixed dosing

Reagents tab

All reagents of the plant with consumption, cost and cost per tonne of ore. Totals per reagent at the bottom.
All reagents of the plant with consumption, cost and cost per tonne of ore. Totals per reagent at the bottom.
UnitReagentDoseConsumptionCost
Ball millLime800 g/t400 kg/h€ 72/h
RougherPAX30 g/t15 kg/h€ 37.5/h
RougherMIBC25 g/t12.5 kg/h€ 26.3/h
CleanerPAX10 g/t5 kg/h€ 12.5/h
Total€ 148/h = € 0.30/t ore

Choose the currency at the bottom of the tab (€, $, £, A$, C$, R, CLP$, PEN S/). The time base of the balance also applies here.

PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Engineering tools › Sankey view

Sankey view

Draw every arrow as wide as its flow and see at a glance where the solids, the water or the metal go.
  1. In the top bar choose 👁 Sankey (flow widths).
  2. In the selector next to it choose the flow: Solids, Water or a component (Cu flow, Au flow…).
  3. The widest arrow carries the largest flow; the legend in the corner shows the maximum. Each label shows the flow and its % of the plant feed.
Copper flow in the concentrator: the recycle between the mill and the cyclone carries 3.6 times the copper of the feed; 90.9 % leaves with the rougher concentrate.
Copper flow in the concentrator: the recycle between the mill and the cyclone carries 3.6 times the copper of the feed; 90.9 % leaves with the rougher concentrate.
Read the pictureThick recycles show where material circulates. A wide arrow into the tailings shows where the metal is lost.

The Sankey view keeps your layout. It is exported to PNG and PDF and shown in shared links like the other view modes.

PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Engineering tools › Data reconciliation

Data reconciliation

When you have more measurements than the balance needs and they do not agree, reconciliation adjusts them as little as possible so that every unit closes.

Why reconcile

Plant measurements always contain errors: weightometers drift, samples are not perfectly representative, assays have a precision. If you enter all flows and grades around a unit, they will rarely close exactly. Reconciliation finds the values closest to your measurements that satisfy every balance.

FeedConcentrateTailingsmeasuredreconciled± measurement error (σ)
Each measurement may move within its error bar. Reconciled values (purple) close the balance.

Method

PfdLabs minimises the weighted sum of squares of the adjustments

SSQ = Σ ( (x̂ − x) / σ )²

subject to the solids, water and metal balance of every unit (weighted least squares with Lagrange multipliers, iterated for the products of flow and grade). σ is the measurement error, set as a relative standard deviation for flows and for grades or concentrations (default 5 %). Values that are calculated, not measured, are free to move.

Reading the results

The Reconcile tab: measured and reconciled values, adjustment in % and in σ.
The Reconcile tab: measured and reconciled values, adjustment in % and in σ.
Column / lineMeaning
Adjustmentreconciled − measured, in %
Adj. / σthe adjustment in units of the measurement error. Above 2 it is shown in orange: a possible gross error.
Redundancynumber of balance equations minus unmeasured values. It must be at least 1.
SSQ and χ² limitif SSQ is below the 95 % χ² limit, the measurements are consistent with their errors.

Example

A rougher with measured flows 500 / 18 / 470 t/h, Cu 1.00 / 25.0 / 0.10 % and solids 33 / 30 / 30 % has a redundancy of 3. Reconciliation gives 494 / 17.96 / 476 t/h with SSQ 2.0, well below the limit of 7.8: the data are consistent. If the concentrate flow is entered as 28 t/h instead, SSQ rises to 22 and the concentrate flow and grade are marked in orange.

  1. Enter all measured values and set the measurement errors.
  2. Check the result and the values in orange. Correct obvious mistakes in the data.
  3. Click Apply reconciled values to replace the inputs with the reconciled values. Ctrl+Z brings the measurements back.
Nothing to reconcile?Reconciliation needs more measurements than the balance needs. With exactly enough data, PfdLabs simply calculates the missing values and there is nothing to adjust.
PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Engineering tools › Report and Excel

Report and Excel

Take the whole balance with you: a printable report for reviews and an Excel workbook for further calculations.

Balance report

Click Report in the stream table or Export → Balance report. A new page opens; use Print / Save as PDF. It contains:

  • title, date, active case, time base and status
  • the whole diagram
  • key results: plant feed, products, recoveries, water
  • stream table and unit balances
  • water balance, reagents, equipment sizing and reconciliation, when present
The first page of the balance report.
The first page of the balance report.

Excel workbook

SheetContent
Stream tableall streams with flows, water, volume, density, grades, metal flows and recoveries
Unit balancesolids in, out, difference and status of every unit
Equipment sizingfeed and results of every sized unit
Reagentsdoses, consumption and cost
Streams <case>, Casesone sheet per case and the comparison

Numbers are written as numbers, with units in the column headers, in the time base you selected. If Excel cannot be loaded, a CSV file is downloaded instead.

PlanThe mass and metal balance and the tools built on it are part of Pro Yearly and Pro Lifetime. Free and Monthly users can enter stream data and see the results in shared links of Yearly and Lifetime users.
Help › Account › Plans

Plans

What each plan includes.
FeatureFreePro MonthlyPro YearlyPro Lifetime
Diagrams in the cloud5unlimitedunlimitedunlimited
All symbols, templates, Save as file✓✓✓✓
PNG and SVG exportwith watermarkcleancleanclean
PDF export–✓✓✓
Share read-only links✓✓✓✓
Mass & metal balance, water balance, SX/EW––✓✓
Cases, sizing, reagents, Sankey, reconciliation, report––✓✓
Price€0€3 / month€29 / year€65 once

Monthly subscribers can switch to Yearly in Dashboard → Manage billing. See Pricing for details.

Without Yearly or Lifetime, the balance button shows what the balance offers.
Without Yearly or Lifetime, the balance button shows what the balance offers.
Help › Account › Troubleshooting

Troubleshooting

Answers to the questions we hear most often.
A unit shows “balanced” but I think the numbers are wrong
A unit is balanced when solids, water and every metal close within 0.5 %. Check that every stream has the right type (a solution drawn as a slurry has no water balance) and the right flow unit. Click the unit to see the in and out values.
A unit shows a warning after I entered every stream
All streams are known, so nothing can be calculated and the measured values disagree. Leave the least reliable value empty, or use data reconciliation.
“water out − in” on a flotation cell
Flotation usually receives spray and dilution water. Draw it as a Water stream into the cell and leave it empty; it is calculated.
The two-product formula does not calculate the split
The unit needs exactly one slurry input and two slurry outputs, the feed flow, and the grades of all three. The concentrate grade must differ from the tailings grade and the split must be between 0 and 100 %.
I do not see the Base case
The Base case appears when you create a second case: + New case… in the top bar case selector.
Nothing to reconcile
There are not more measurements than the balance needs. Add measured flows or grades on streams that are now calculated.
Recovery is shown “of S3” and not of the plant feed
The plant feed has no grade for that metal. Enter the grade on the first stream (ore pile, ROM) to get recoveries of the plant feed.
Values do not change when I type
Grey italic text in a field (“e.g. 1.05”) is only a hint. Type a number into the field.
The report does not open
Allow pop-ups for pfdlabs.com in your browser.
My Monthly plan does not show the balance
The balance is part of Pro Yearly and Lifetime. Switch in Dashboard → Manage billing.